高水头船闸平底廊道反弧形阀门净动水启门力恒定流试验*
DOI:
CSTR:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

国家重点研发计划(2016YFC0402001)


Steady flow experiment on net hydrodynamic uplifting force of reversed tainter value in flat-bottom galleries of high-head lock
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    通过恒定流试验对平底廊道反弧形阀门净动水启门力进行了研究,结果表明:1)底缘压力下降是反弧形阀门产生净动水启门力的最主要原因;2)各开度下反弧形阀门净动水启门力与孔口水流弗劳德数的平方成线性关系;3)阀门厚度变化对反弧形阀门最大净动水启门力影响较小。

    Abstract:

    Net hydrodynamic uplifting force of reversed tainter value in flat-bottom galleries of high-head lock was studied through steady flow tests,main result as follows:1)The pressure decreased on hemline is the main reason that increase net hydrodynamic uplifting force;2)The net hydrodynamic uplifting force of reversed tainter value has linear relation with square of Froude number of orifice current in every opening;3)The thickness change of value has little influence on the maximum net hydrodynamic uplifting force.