    摘要:

    结合国内某船闸工程,针对集中输水系统中简单消能工和格栅消能室两种布置形式,采用RNG κ-ε紊流模型和自由水面处理技术的VOF法对输水过程闸室流态进行计算,在此基础上分析了集中输水系统镇静段长度的选择方法,给出合理的量化方法。两种典型集中输水系统计算表明,以闸室沿程平均紊动能小于0.02 m2/s2作为镇静段长度控制条件,确定的镇静段长度与规范相符且更明确,可以作为集中输水系统镇静段长度量化判别指标。

    Abstract:

    Combining with a domestic ship lock project,flow regime in chambers of two types of filling system through the head,in which setted simple energy dissipater and grid stilling chamber,was simulated by RNG κ-ε turbulence model and VOF method.Based on analysis of the simulation,a reasonable quantitative method was given.This simulation turned out that taking turbulence flow energy less than 0.02 m2/s2 as a quantitative indicator to determine the length of mitigative section during filling process meet the norms.