Operation reliability evaluation of arc-type ship’s anti-collision facility
DOI:
CSTR:
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    The operation reliability of arc-type ship’s anti-collision facility directly relates to daily operational flexibility and security, so it is of great significance to study it. The operation reliability is quantified to the possibility that driving force is bigger than the resistance with the performance reliability evaluation model.In order to improve the test efficiency, the test program is optimized by the enhanced test model. The mechanism model is established, and four strain measurement units are laid on the junction between collision belt and buoy.The mechanism model test results show that, under the condition of strengthened test, no abnormal output occurs in 25 test cycles and the buoy stuck didn’t appear in 25 test cycles. It proves that the design of the facilities meets the reliability requirements.

    Reference
    Related
    Cited by
Get Citation

吴 俊,余 葵,胥润生,李晓飚,刘 洋,马希钦.大水位差拱形桥梁弧形自浮式防船撞设施运行可靠性强化试验研究*[J].水运工程,2013,(1):66-70

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:
  • Revised:
  • Adopted:
  • Online: January 15,2013
  • Published:
Article QR Code