    摘要:

    随着港口建设的快速发展,高效、快速处理新近吹填淤泥成为迫切需要解决的问题。在现场试验的基础上,结合各项监测及检测结果,分析真空预压加固机理,对比不同类型滤膜排水板的加固效果,并研究不同类型滤膜排水板的淤堵情况。试验结果表明:采用防泥蝶形接头直接连接排水板和钢丝软管,可很好地提高真空度的传递效率,管到排水板的真空度损失小;抽真空过程中,土中细颗粒随着水向排水板附近移动形成“土柱”,距排水板越远,孔压消散越差,土体的剪切强度越小,结合孔压监测数据和土体剪切强度值分析得到“土柱”的深度范围为1.5~2.0 m,进口滤膜排水板的处理效果优于合资滤膜排水板,普通滤膜排水板处理效果最差;处理后排水板的渗透系数仍能满足设计要求,土体的渗透系数随着距排水板距离的减小而减小,板间土处理较差主要原因是“土柱”阻碍了真空度向周围土体的传递。

    Abstract:

    With the rapid development of port construction,the foundation treatment of newly reclaimed silt becomes the problem which is needed to solve urgently.On the basis of field test,combining the results of each monitoring and testing,and in order to analyze the strengthening mechanism of vacuum preloading and contrast the reinforcement effect of different types of drainage plate,we study the clogging of different types of drainage plates.The testing results indicate that the connecting drainage plate and steel wire hose by new butterfly joint directly improve the transfer efficiency of vacuum degree greatly,and the vacuum degree tube to drainage plate just has small loss.During the vacuum pumping,the fine particles in soil moving toward the drainage plate with water forms the “soil column”,the pore pressure dissipation and shear strength become less with the increase of distance between drainage plate and soil.The depth range of “soil column is 1.5 m to 2.0 m based on the analysis of pore pressure dissipation and shear strength of soil.Analyzing the treatment effect of different types of drainage plates,we know that the imported membrane drainage plate is better than the the joint-ventured membrane drainage plate,and the joint-ventured is better than the ordinary membrane drainage plate.The permeability coefficient of drainage plate after treatment still meets the design requirements,and the permeability coefficient of soil reduces with the decrease of distance between the drainage plate and soil.The cause of bad treatment of soil between drainage plates is that “soil column” blocks the transfer of vacuum degree to surrounding soil.

    参考文献
    相似文献
    引证文献
引用本文

蒋杰,闫伟.不同类型滤膜排水板真空预压现场试验研究[J].水运工程,2017(2):149-154.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2017-02-19
  • 出版日期:
文章二维码